Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The test procedure was designed to be compatible with Method 104 specified in the OECD Guidelines for Testing of Chemicals, 23 March 2006. 
The test item has been determined to have a vapour pressure of 1.1 x 10ˆ-2 Pa at 25°C, using a vapour pressure balance.

Key value for chemical safety assessment

Vapour pressure:
0.011 Pa
at the temperature of:
25 °C

Additional information

A reliability rating of 1 was assigned to the key study, according to the criteria of Klimisch, 1997 as the study was conducted in accordance with recognised guidelines and GLP.