Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
bis(11-methyldodecyl) ((((1,3-phenylenebis(methylene)bis(azanediyl))bis(carbonyl) bis(azanediyl))bis(4-methyl-3,1-phenylene) dicarbamate
Cas Number:
865536-03-4
Molecular formula:
C52H80N6O6
IUPAC Name:
bis(11-methyldodecyl) ((((1,3-phenylenebis(methylene)bis(azanediyl))bis(carbonyl) bis(azanediyl))bis(4-methyl-3,1-phenylene) dicarbamate
Constituent 2
Chemical structure
Reference substance name:
bis(11-methyldodecyl)(4-methyl-1,3-phenylene)dicarbamate
Molecular formula:
C35H62N2O4
IUPAC Name:
bis(11-methyldodecyl)(4-methyl-1,3-phenylene)dicarbamate
Constituent 3
Chemical structure
Reference substance name:
11-methyldodecyl (3-(3-(3-(aminomethyl)benzyl)ureido)-4-methylphenyl)carbamate
Molecular formula:
C30H46N4O3
IUPAC Name:
11-methyldodecyl (3-(3-(3-(aminomethyl)benzyl)ureido)-4-methylphenyl)carbamate
Constituent 4
Chemical structure
Reference substance name:
1,1'-(4-methyl-1,3-phenylene)bis(3-(3-(aminomethyl)benzyl)urea)
Molecular formula:
C25H30N6O2
IUPAC Name:
1,1'-(4-methyl-1,3-phenylene)bis(3-(3-(aminomethyl)benzyl)urea)
Test material form:
solid

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
> 15 min

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
In the screening test, propagation of the flame over 200 mm took much more than four minutes. Therefore, the test item Addukt TI 65 - MXDA should be considered as not highly flammable. No observations were made which might cause doubts concerning the validity of the study outcome.
Executive summary:

First, a safety test was performed. A small amount of the test item was heated on a magnesia groove with a gas burner in order to derive safety precautions. The test item melted

to a yellow liquid, which boiled and finally carbonised. When ignited with the flame of a teclu burner, the test item started to burn with a big yellow flame. In the screening test, propagation of the flame over 200 mm took much more than four minutes. Therefore, the test item Addukt TI 65 - MXDA should be considered as not highly flammable.