Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
The study was conducted between 20 May 2016 and 01 June 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Version / remarks:
30 May 2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Sponsor Lot/Barch number 5399561P10
- Expiration date of the lot/batch: 25 January 2020
- Purity test date: 26 January 2016

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Room teperature in the dark
Key result
Remarks on result:
no self-ignition observed up to the melting point
Remarks:
The test item has been determined not to have a relative self-ignition temperature below its melting temperature

The test item was an off white solid. Whilst heating the test item, no relevant exothermic reaction/self-heating of the sample has been observed. On completion of the test, the test item had melted.

Conclusions:
The test item was an off white solid. Whilst heating the test item, no relevant exothermic reaction/self-heating of the sample has been observed. On completion of the test, the test item had melted.

Description of key information

The test item was an off white solid. Whilst heating the test item, no relevant exothermic reaction/self-heating of the sample has been observed. On completion of the test, the test item had melted.

Key value for chemical safety assessment

Additional information

The test item has been determined not to have a relative self-ignition temperature below its melting temperature.