Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Remarks:
Tremain (2002a) IIA 02/19
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes
Specific details on test material used for the study:
IR5878 Technical grade
98.56% pure
Batch number G 009/02
White powder
Stored at room temperature in the dark
Date received 23 July 2002
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks:
Did not propagate combustion over 200mm
Moisture (wt %):
0.14
Remarks on result:
other: The pile melted then ignited but self extinguished after propagating combustion over 35mm in 3 min 42 seconds.
Remarks:
The result of the preliminary screening test obviated the need to perform the main test.
Interpretation of results:
not classified based on GHS criteria
Conclusions:
IR5878 (orthosulfamuron) is not highly flammable. The test material did not propagate combustion over the 200mm of the preliminary screening test.
Executive summary:

IR5878 (orthosulfamuron) is not highly flammable.

Description of key information

IR5878 (orthosulfamuron) is not highly flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

IR5878 (orthosulfamuron) is not highly flammable.