Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-01-03
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
150 °C
Remarks on result:
other: no pressure stated

The Flashpoint is an empirical measurement rather than a fundamental parameter. The measured value will vary with equipment and test protocol variations, including temperature rate ramp (in automated testers), time allowed for the sample to equilibrate, sample volume, and whether the sample is stirred.

Interpretation of results:
other: EU GHS criteria not met
Conclusions:
Flashpoint of the test substrate is 150 °C.
Executive summary:

The flash point of the test substrate was determined according to ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester) to be 150 °C.

Description of key information

The flash point of the test substrate was determined according to ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester) to be 150 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
150 °C

Additional information

In the study report no pressure was stated, but it can be assumed, that standardised conditions were uses.