Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Batch 3033900250
Key result
Remarks on result:
no self ignition observed under the test conditions
Conclusions:
The relative self-ignition temperature of the sample was determined according to EU Method A.16. No exothermic reaction was observed during the test (heating of the oven up to 400°C).
Executive summary:

The relative self-ignition temperature of the sample was determined according to EU Method A.16. No exothermic reaction was observed during the test (heating of the oven up to 400°C).

Description of key information

The relative self-ignition temperature of the sample was determined according to EU Method A.16. No exothermic reaction was observed during the test (heating of the oven up to 400°C).

Key value for chemical safety assessment

Additional information