Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Principles of method if other than guideline:
Method takes also OECD Guideline 110 into account.
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Specific details on test material used for the study:
Batch 3033900250
Mass median aerodynamic diameter:
22.58 µm
Geometric standard deviation:
1.146
Percentile:
D90
Mean:
11.8 µm
St. dev.:
0.028
Percentile:
D50
Mean:
9.76 µm
St. dev.:
0.005
Percentile:
D10
Mean:
8.09 µm
St. dev.:
0.018
Conclusions:
The particle size of the test substance was determined with Laser Diffraction on 5 runs according to ISO 13320, CIPAC MT 187 and taking OECD guideline 110 into account. The following average results were obtained:

D10: 8.09 µm +- 0.0180 µm
D50: 9.76 µm +- 0.00524 µm
D90: 11.80 µm +- 0.0281 µm
MMAD : 22.58 µm +- 0.011 µm
Executive summary:

The particle size of the test substance was determined with Laser Diffraction on 5 runs according to ISO 13320, CIPAC MT 187 and taking OECD guideline 110 into account. The following average results were obtained:


D10: 8.09 µm +- 0.0180 µm
D50: 9.76 µm +- 0.00524 µm
D90: 11.80 µm +- 0.0281 µm
MMAD : 22.58 µm +- 0.011 µm

Description of key information

The particle size of the test substance was determined with Laser Diffraction on 5 runs according to ISO 13320, CIPAC MT 187 and taking OECD guideline 110 into account. The following average results were obtained:


D10: 8.09 µm +- 0.0180 µm
D50: 9.76 µm +- 0.00524 µm
D90: 11.80 µm +- 0.0281 µm
MMAD : 22.58 µm +- 0.011 µm

Additional information