Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: EU method. GLP study.
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Remarks on result:
other: The sample temperature in these compartments, does not exceed the temperature criterion 400 °C, so the test item is not self-ignitable in accordance with test A.16.

On the graph temperature versus time there are exothermic changes of the sample between the temperature of oven 195 – 250 °C and 300 – 350 °C connected with self-ignition of the components of the reaction mixtures. The sample temperature in these compartments, does not exceed the temperature criterion 400 °C, so the test item is not self-ignitable in accordance with test A.16.

Conclusions:
The test item is not self-ignitable in accordance with test A.16.
Executive summary:

The determination of the relative self-ignition temperature of the test substance was performed according to EU method A.16. A certain volume of the substance is placed in an oven at room temperature; the temperature / time curve relating to condition in the centre of the sample is recorded while the temperature of the oven is increased to 400 °C, or to the melting point if lower, at a rate of 0.5 °C/min.

The sample temperature does not exceed the temperature criterion 400 °C, so the test item is not self-ignitable in accordance with test A.16.

Description of key information

Key study: EU method. GLP study.

The test item is not self-ignitable in accordance with test A.16. as it is packed in less than 3m3.

Key value for chemical safety assessment

Additional information

Key study: EU method. GLP study.