Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04 Sept 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
other: MIL-DTL-248D
Principles of method if other than guideline:
4.4.8. Thickness of flake (applicable to Type I and Type III TNT only). The thickness of each of 100 flakes of TNT shall be measured by means of a micrometer accurate to at least 0.001 inch. The maximum thickness shall be noted and the average thickness calculated.
GLP compliance:
no
Type of method:
other: Method 204.1 of MIL-STD-650
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Key result
Mean:
0.022 other: inch
Remarks on result:
other: thickness of flakes avarage

Description of key information

Thickness of flakes anarage: 0.022 inch

Additional information