Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
1983
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D3278 (Standard test methods for flash point of liquids by small scale closed-cup apparatus)
Version / remarks:
89
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
85 °C
Atm. press.:
101.325 kPa
Remarks on result:
other: Flash point: 85 ± 2° C
Interpretation of results:
Category 4 (combustible liquids) based on GHS criteria
Conclusions:
In a test according to EEC A.9 , the flash point of EGForm was determined to be 85°C.

Description of key information

The flash point of the test substance was determined in a test according to EEC A.9.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
85 °C

Additional information