Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
September 2014
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
not specified
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
100.5 °C
Atm. press.:
101.325 kPa
Remarks on result:
other: measured at a pressure of 97.6kPa, corrected for a pressure of 101.325kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The Flash point of the test substance was determined to be 100.5°C ± 0.5 °C (measured at a pressure of 97.6kPa, corrected for a pressure of 101.325kPa). Based on the results of this study, the test substance is not classified as a flammable liquid according to Regulation (EC) No 1272/2008 (CLP).
Executive summary:

The flash point of the test substance was determined according to EU method A9 with the Pensky-Martens closed cup test (non-equilibrium method). The corrected average flash point based on three measurements corresponds to 100.5°C ± 0.5 °C (measured at a pressure of 97.6kPa, corrected for a pressure of 101.325kPa). Based on the results of this study, the test substance is not classified as a flammable liquid according to Regulation (EC) No 1272/2008 (CLP).

Description of key information

The flash point of the test substance was determined according to EU method A9 with the Pensky-Martens closed cup test (non-equilibrium method). The corrected average flash point based on three measurements corresponds to 100.5°C ± 0.5 °C (measured at a pressure of 97.6kPa, corrected for a pressure of 101.325kPa).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
100.5 °C

Additional information

Based on the results of this study, the test substance is not classified as a flammable liquid according to Regulation (EC) No 1272/2008 (CLP).