Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
Experimental tests performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
other: Refer below principle
Principles of method if other than guideline:
Lowest temperature determined at which substance vaporizes to form an ignitable mixture in air
GLP compliance:
no
Key result
Atm. press.:
965 hPa
Remarks on result:
other: Test chemical did not catch fire on being exposed to air at room temperature of 35ºC
Conclusions:
Test chemical did not catch fire on being exposed to air at room temperature of 35º C at 965 hPA. This indicates that the test chemical was non auto-flammable.
Executive summary:

Test chemical did not catch fire on being exposed to air at room temperature of 35º C at 965 hPA. This indicates that the test chemical was non auto-flammable.

Description of key information

Test chemical did not catch fire on being exposed to air at room temperature of 35º C at 965 hPA. This indicates that the test chemical was non auto-flammable.

Key value for chemical safety assessment

Additional information

Test chemical did not catch fire on being exposed to air at room temperature of 35º C at 965 hPA. This indicates that the test chemical was non auto-flammable.