Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
according to guideline
Guideline:
other: DIN 53015
GLP compliance:
no
Type of method:
forced ball viscometer (dynamic)
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
>= 18 - <= 23

Description of key information

Dynamic viscosity: 18-23 mPa s (DIN 53015, forced ball viscometer)

Key value for chemical safety assessment

Viscosity:
20.5 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information