Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Explosiveness

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosiveness, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
December 15, 2000- March 21, 2001
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: EC method A.14
GLP compliance:
yes
Specific details on test material used for the study:
Methomyl technical
DPX-1179-512
Purity 98.02%
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks:
The BAM fall hammer test
Remarks on result:
other: No signs of ignition or explosion on impact. No signs of decomposition after test assembly dimantled.
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
other: No signs of ignition or explosion; indications of decomposition.
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Value:
6
Remarks on result:
other: Tube recovered intact
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Value:
2
Remarks on result:
other:
Remarks:
Tube recovered intact
Interpretation of results:
GHS criteria not met
Conclusions:
The test substance was found not to be explosive in the thermal, impact, or friction sensitivity tests.
Executive summary:

Tests for explosive properties were carried out on the test substance according to EC Method A14. The test substance was found to be not explosive.

Description of key information

EU A.14

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

Substance was not explosive in a test according to EU A.14; therefore, no classification is required according to EU Classification, Labelling and Packaging of Substances and Mixtures (CLP) Regulation (EC) No. 1272/2008.