Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April 7, 2010- May 12, 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: EEC A.10
GLP compliance:
yes
Specific details on test material used for the study:
Methomyl
DPX-X1179-599
Purity 99.6%
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
<= 2 min
Remarks on result:
other: substance does not ignite by burning with flame along 250 mm x 20 mm x 10 mm of the powder train within the 2 minutes test period
Interpretation of results:
not classified based on GHS criteria
Conclusions:
Test item DPX-X1179 was not highly flammable material.
Executive summary:

The study was conducted to determine the flammability of DPX-X1179 as per the guidelines EEC A.10. Based on the flammability study, DPX-X1179 was not a highly flammable material.

Description of key information

EEC A.10

Key value for chemical safety assessment

Flammability:
not classified

Additional information

not flammable

Justification for classification or non-classification

Substance was not flammable in a test according to EEC A.10; therefore, no classification is required according to EU Classification, Labelling and Packaging of Substances and Mixtures (CLP) Regulation (EC) No. 1272/2008.