Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
pyrophoric liquids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:
Endpoint:
flammable solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid

Description of key information

highly flammable liquid
no pyrophoricity
no flammibility in contact with water


not self-heating

Key value for chemical safety assessment

Flammability:
highly flammable

Additional information

Based on flash point and boiling point the substance is a highly flammable liquid. Based on the chemical structure and experience in handling and use, pyrophoricity, flammability in contact with water and self-heating are not expected.

Justification for classification or non-classification

The available data on the flash point and the boiling point of the test substance meet the criteria for classification as flammable liquid cat. 2 (H225) according to Regulation (EC) 1272/2008.