Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Description of key information

not oxidising

Key value for chemical safety assessment

Oxidising properties:
no

Additional information

The oxidising properties of the test item were determined by EU Method A.17. The test item was not ignite at any proportion (10 - 90% test item in cellulose). The test item demonstrated no oxidizing properties under the conditions of this test.

Justification for classification or non-classification

The available data on oxidising properties of the test substance do not meet the criteria for classification according to Regulation (EC) 1272/2008 and are therefore conclusive but not sufficient for classification: The maximum burning rate of the test mixture was less than that of the reference mixture (4:6 barium nitrate and cellulose) in a test according to EU Method A.17. Due to the fact the no proportion of the test item could at any concentration be ignite this test can be used for classifcation.